Lutron
Salt Meter Lutron YK-31SA
Lutron YK-31SA Salt Meter with separtate probe is a convenient & efficient way to measure Salt content up to 10%.
Resistance Decade Box Lutron RBOX-408
Lutron RBOX-408 Resistance Box is a useful device use in school & all industries.
Power Clamp-On Tester Lutron PC-6009
Lutron PC-6009 Power Clamp-On Tester is an economic method to measure Power up to 10,000 Watts.
Power Analyzer Lutron PC-6011SD
Lutron PC-6011SD measure & save data on SD Card. Analysis TOTAL HARMONIC DISTORTION, Graphic phase diagram & capture transient events (Dip, Swell, and outrage)
PH Meter with External Probe Lutron YK-21PH
Lutron YK-21PH PH Meter is high quality general purpose PH measurement accuracy of 0.1 PH. *External PH Probe PE-03 & PH7 Calibration Solution is provided as package.
PH Meter with External Probe Lutron PH-220
Lutron PH-220 Waterproof PH Meter with External Probe is capable of measure PH with resolution of 0.1 PH. *PH Probe & Calibration Solution (PH4/PH7) is provided as package.
PH Meter with External Probe & SD Memory Lutron PH-230SD
Lutron PH-230SD PH Meter is high quality PH measurement accuracy of 0.01PH. *External PH Probe PE-03 & PH7 Calibration Solution is provided as package.
PH Controller Lutron PPH-2108
Lutron PPH-2108 is a PH & Temp. Controller with 3 Alarms settings. PH & Temp Probe is an option selection.
Oxygen Meter (02) Lutron DO-5510HA
Lutron DO-5510HA beside measure oxygen in Air (100%) but also measure DO & Temperature.
ORP Meter Lutron YK-23RP
Lutron YK-23RP ORP Meter with external probe is a capable of measure ORP range of + & - 2000mV.
Noise Dosimeter Lutron DS-2013SD
LUTRON DS-2013SD is an economic Noise Dosimeter capable of measure exposure of noise over a period of time. It often use for occupational Safety & Health.
Negative Ion Meter Lutron NI-214
Lutron NI-214 Negative Ion (ORP) Meter with external probe is a capable of measure ORP range of + & - 2000mV.
Moisture Meter (Wood/Concrete) Lutron PMS-713
Lutron PMS-713 with built-in test pins offer an economic alterative to measure Concrete (relative up to 100%) & Wood ( up to 40%).
Moisture Meter (Wood/Concrete) Lutron MS-7003
Lutron MS-7003 with built-in test pins for easy measure of Concrete (relative up to 100%) & Wood ( up to 40%).
Moisture Meter (Wood) Lutron MS-7000HA
Lutron MS-7000HA with external probe (pins type) measure 9 grouping of wood speices based on their density or hardness.
Moisture Meter (Soil) Lutron PMS-714
Lutron PMS-714 with built-in Probe measure Moisture content of soil up to 50%.
Milliohm Meter Lutron MO-2013
Lutron MO-2013 bench type Milliohm Meter capable of measure low contact resistance with 0.001 milliohm resolution.
Milliohm Meter Lutron MO-2001
Lutron MO-2001 Milliohm Meter using kelvin clips to measure low CONTACT resistance.
Milli Gauss (Magnetic) Meter (DC & AC) Lutron GU-3001
Lutron GU-3001 precision Milli Guass Meter capable to measure milligauss(mG) from -300mG to 3000mG.
Clock
Conductivity-TDS Tester
Control, Process, Display
Dissolved Oxygen (DO) Meter
Electrical
Electronic
Environmental
Gas Detector
Gas Detector Calibration Singapore
Confined places have fewer or no exits or entryways. These properties make it possible for gas levels to shift quickly, making the atmosphere hazardous with little warning. Entrants and whole watchers in confined spaces need to know if the place is safe and if conditions are going toward danger to make informed judgments regarding their safety in advance.
What is the Risk?
Dangerous gases are only one of the many dangers that might develop when working in a small area. Hazardous gases in enclosed areas pose a significant risk to workers exposed to fumes, vapours, or oxygen deprivation, leading to unconsciousness or asphyxiation.
How is the Gas Detector Protected?
The best gas detector Confined space allows you to test the environment before entering, measure continuously while inside and is simple to use and dependable to rely on.
Gas Detector Confined space monitors for dangerous fumes, gases and vapours, and oxygen deprivation to maintain occupational health and safety compliance to safeguard workers from harm. The concentration of combustible gases can be monitored with a personal multi-gas monitor, and an alarm will sound if concentrations are near the Lower Explosive Limit.
Our Gas Detector Works Best:
Numerous Gas Detector Confined space and leak detection devices are available from JUTECH. We hope to make gas leak detection more precise with our devices while making it as easy as possible.
Our technologies have been enhanced to provide trustworthy and high-quality goods throughout the years. Our gas detectors are custom-made to meet the needs of a wide range of industrial applications. It doesn't matter where our clients are, they can rely on them to quickly and accurately detect and avoid problems.
Why is Calibration Important?
Operating gas detection instruments and systems that are not kept up to date may not provide any warning of a hazardous leak or the presence of a potentially life-threatening environment. Gas detector calibration Singapore, servicing, and inspection are all essential parts of the maintenance process for any gas detection system.
Our Calibration Service:
In addition to supplying equipment, we offer consultation services for the customization, installation, and maintenance of gas monitoring systems and a variety of gas detector calibration Singapore and repair services, from essential calibration to sensor replacements and repairs.
Robust sensor technology and calibration offer faster reactions in our gas detectors. Respond in milliseconds instead of minutes or hours, and you could save a life.
Regular Checkup:
You must first calibrate your gas detector to guarantee that it accurately detects gas levels. The monitor must be calibrated by exposing it to a known calibration gas concentration or test gas for a predetermined period. Using this reading as a reference point, the gas detector will take future readings. To ensure reliable measurements, repeat this method every month. Gas detector calibration in Singapore is necessary because sensors wander over time, and toxins and inhibitors can alter gas readings.
You'll need calibration gas and tubing, a docking station, and a timer for automatic calibration. You can use a docking station to keep track of your gas detector's calibration history and create certifications for compliance when you calibrate your device.
Industrial & Mechanical
Multifunctional Tester
Multimeter
Power Converter / Charger
Process Calibrator
Telecom
Temperature & Humidity
Humidity Temperature Meter
One of the most used techniques is taking readings of the air's temperature and humidity. A reputable humidity meter is needed for accurate readings. Objects may be measured in terms of their heat or coolness by using temperature.
Temperature is one of the seven basic physical variables in the ISU. Humidity is defined as the quantity of water vapour in the air. The most common method of expressing relative humidity is as a percentage. Temperature and RH go hand in hand. In confined gas, higher temperatures diminish relative humidity. Humidity measures the amount of water vapour in the air. The relative humidity is the ratio of water vapour in the air to total water vapour
Measurement is necessary to ensure no abnormalities in the industry's temperature and humidity systems.
What is the Need for a Humidity Temperature Meter?
Measurement of temperature and humidity is necessary for temperature and humidity control systems to work. In addition, it guarantees a safe working environment and the safe storage of raw materials, components, completed goods, and equipment in excellent condition. Numerous temperature and humidity sensors are placed all over the place in almost every lab, warehouse, production hall, and workroom.
Temperature and humidity measurements are used in all labs, research institutions, and industries, including security, pharmaceutical, calibration laboratories, aviation, metals, and castings. Cement is used in various products, from seeds to medical equipment to colleges, museums to nuclear reactors. It is also used in various other products, including crystals, semiconductors, electronics, food and beverages, and optics.
Temperature and relative humidity (RH) both influence how pleasant a place is to be in. Monitors that display real-time measurements like JUTECH's Analog Humidity-
Specs and Features of JUTECH Humidity - Temperature Meter:
The JUTECH Humidity Temperature Meter measures interior temperature and humidity quickly and precisely, making it ideal for usage in office buildings, warehouses, manufacturing facilities, and server rooms, among other places.
In addition, you may get the dew point and wet bulb temperature from the easy-to-use measurement device. Both numbers provide information about the temperature-humidity connection and critically evaluate the interior environment. It is easy to use and has reliable technology.
The JUTECH Humidity Temperature Meter has a built-in NTC temperature sensor that provides excellent temperature measurement accuracy. This thermo hygrometer uses a capacitive humidity sensor known for its long-term durability to detect humidity.
Temperature and humidity readings are visible on the LED display of the thermo hygrometer. Additional features include dew point and wet bulb temperature calculations and min. /maximum values for these parameters. Temperature and humidity measurements may be made with the JUTECH Humidity Temperature Meter's clip-on protective hat, wrist strap, and belt.