Lutron
Vibration Meter Lutron VB-8206SD
Lutorn VB-8206SD measure machinery vibration with 3 parameters reading such as Velocity, Acceleration & Displacement. It provide with a separate probe & magnetic head. It also able to perform data-logging function with SD Card memory.
Vibration Meter Lutron VB-8202
Lutorn VB-8202 measure machinery vibration with Velocity (MAX 200mm/s) & Acceleration (200m/s2). It provide with a magnetic & shalf-type of sensor head.
Vibration Meter Lutron VB-8201HA
Lutorn VB-8201HA measure machinery vibration with Velocity (MAX 200mm/s) & Acceleration (200m/s2). It provide with a separate probe & magnetic sensor head.
Vacuum Meter (1500 mbar) Lutron VC-9200
Lutron VC-9200 measure absolute vacuum or pressure (MAX 1500 mbar) & with 8 kinds of Display selection.
Turbidity Meter Lutron TU-2016
Lutron TU-2016 Turbidity Meter is a professional tester for measure Turbidity up to 1,000 NTU.
True RMS AC/DC Clamp-On Meter (AC/DC 2000A) Lutron CM-9930
Lutron CM-9930 AC/DC Clamp-On Meter capable of measure both AC and DC Current up to 2000A.
Tachometer Lutron DT-2236
Lutron DT-2236 Tachometer capable of measure RPM up to 100K (photo) & 20K (Contact).
Tachometer Lutron DT-2230
Lutron DT-2230 Pocket type Tachometer capable of measure RPM up to 100K RPM (photo) & 20K RPM (Contact).
Stroboscope Lutron DT-2199
Lutron DT-2199 DC-Powered Stroboscope use long lasting LED to measure RPM (MAX 100,000RPM)
Sound Level Meter Lutron SL-4010
Lutron SL-4010 is a basis Sound Level Meter used by safety official in Health & Industrial application.
Sound Calibrator Lutron SC-942
Lutron SC-942 Calibrator is a useful meter to test Sound Level Meter on 94 & 114 dB range.
Single Phase Power Analyzer Lutron DW-6090
Lutron DW-6090 Single Phase Power Analyzer capable of testing WATTS (TRUE RMS), VA, Whr, PF (Power Factor), ACV, ACA, DCV, DCA, HZ.
Single Phase AC/DC Power Analyzer Lutron DW-6090A
Lutron DW-6090A Single Phase Power Analyzer capable of testing WATTS (True RMS), VA, Whr, PF(Power Factor), ACV, ACA, DCV, DCA, HZ.
Single / 3 Phase Power Analyzer with SD Card Datalogging Lutron DW-6093
Lutron DW-6093 Single and 3 Phase Power Analyzer capable of testing WATTS (TRUE RMS), VA, Whr, PF (Power Factor), ACV, ACA, DCV, DCA,HZ. It measures a MAX Power of 10M Watts (Depend on the type of clamp use)
Single / 3 Phase Power Analyzer & HARMONICS with SD Card Datalogging Lutron DW-6095
Lutron DW-6095 Single and 3 Phase Power Analyzer capable of testing WATTS (TRUE RMS), VA, Whr, PF (Power Factor), ACV, ACA, HZ & HARMONIC feature (1 to 50 orders)
SD Card Sound Level Meter Lutron SL-4033SD Type 1
Lutron SL-4033SD is a Type 1 Sound Level Meter which able to perform Datalogging function by using SD Card memory. Data is retrieved on Excel program.
SD Card Memory Sound Level Meter Lutron SL-4023SD
Lutron SL-4023SD is a Type 2 Sound Level Meter which able to perform Datalogging function by using SD Card memory. Data is retrieved on Excel program.
Scales (600gm) Lutron GM-610P
Lutron GM-610P Digital Scales with Counting function measure up to MAX 600 grams at 0.01gm resolution. The platform (Tray) size is 120mm diameter.
Scales (600gm) Lutron GM-600G
Lutron GM-600G Digital Scales with Counting function measure up to MAX 600 grams at 0.1gm resolution. The platform (Tray) size is 195 x 150 (mm).
Scales (3KG) Lutron GM-3KG
Lutron GM-3KG Digital Scales with Counting function measure up to MAX 3KG at 1gm resolution. The platform (Tray) size is 195 x 150 (mm).
Clock
Conductivity-TDS Tester
Control, Process, Display
Dissolved Oxygen (DO) Meter
Electrical
Electronic
Environmental
Gas Detector
Gas Detector Calibration Singapore
Confined places have fewer or no exits or entryways. These properties make it possible for gas levels to shift quickly, making the atmosphere hazardous with little warning. Entrants and whole watchers in confined spaces need to know if the place is safe and if conditions are going toward danger to make informed judgments regarding their safety in advance.
What is the Risk?
Dangerous gases are only one of the many dangers that might develop when working in a small area. Hazardous gases in enclosed areas pose a significant risk to workers exposed to fumes, vapours, or oxygen deprivation, leading to unconsciousness or asphyxiation.
How is the Gas Detector Protected?
The best gas detector Confined space allows you to test the environment before entering, measure continuously while inside and is simple to use and dependable to rely on.
Gas Detector Confined space monitors for dangerous fumes, gases and vapours, and oxygen deprivation to maintain occupational health and safety compliance to safeguard workers from harm. The concentration of combustible gases can be monitored with a personal multi-gas monitor, and an alarm will sound if concentrations are near the Lower Explosive Limit.
Our Gas Detector Works Best:
Numerous Gas Detector Confined space and leak detection devices are available from JUTECH. We hope to make gas leak detection more precise with our devices while making it as easy as possible.
Our technologies have been enhanced to provide trustworthy and high-quality goods throughout the years. Our gas detectors are custom-made to meet the needs of a wide range of industrial applications. It doesn't matter where our clients are, they can rely on them to quickly and accurately detect and avoid problems.
Why is Calibration Important?
Operating gas detection instruments and systems that are not kept up to date may not provide any warning of a hazardous leak or the presence of a potentially life-threatening environment. Gas detector calibration Singapore, servicing, and inspection are all essential parts of the maintenance process for any gas detection system.
Our Calibration Service:
In addition to supplying equipment, we offer consultation services for the customization, installation, and maintenance of gas monitoring systems and a variety of gas detector calibration Singapore and repair services, from essential calibration to sensor replacements and repairs.
Robust sensor technology and calibration offer faster reactions in our gas detectors. Respond in milliseconds instead of minutes or hours, and you could save a life.
Regular Checkup:
You must first calibrate your gas detector to guarantee that it accurately detects gas levels. The monitor must be calibrated by exposing it to a known calibration gas concentration or test gas for a predetermined period. Using this reading as a reference point, the gas detector will take future readings. To ensure reliable measurements, repeat this method every month. Gas detector calibration in Singapore is necessary because sensors wander over time, and toxins and inhibitors can alter gas readings.
You'll need calibration gas and tubing, a docking station, and a timer for automatic calibration. You can use a docking station to keep track of your gas detector's calibration history and create certifications for compliance when you calibrate your device.
Industrial & Mechanical
Multifunctional Tester
Multimeter
Power Converter / Charger
Process Calibrator
Telecom
Temperature & Humidity
Humidity Temperature Meter
One of the most used techniques is taking readings of the air's temperature and humidity. A reputable humidity meter is needed for accurate readings. Objects may be measured in terms of their heat or coolness by using temperature.
Temperature is one of the seven basic physical variables in the ISU. Humidity is defined as the quantity of water vapour in the air. The most common method of expressing relative humidity is as a percentage. Temperature and RH go hand in hand. In confined gas, higher temperatures diminish relative humidity. Humidity measures the amount of water vapour in the air. The relative humidity is the ratio of water vapour in the air to total water vapour
Measurement is necessary to ensure no abnormalities in the industry's temperature and humidity systems.
What is the Need for a Humidity Temperature Meter?
Measurement of temperature and humidity is necessary for temperature and humidity control systems to work. In addition, it guarantees a safe working environment and the safe storage of raw materials, components, completed goods, and equipment in excellent condition. Numerous temperature and humidity sensors are placed all over the place in almost every lab, warehouse, production hall, and workroom.
Temperature and humidity measurements are used in all labs, research institutions, and industries, including security, pharmaceutical, calibration laboratories, aviation, metals, and castings. Cement is used in various products, from seeds to medical equipment to colleges, museums to nuclear reactors. It is also used in various other products, including crystals, semiconductors, electronics, food and beverages, and optics.
Temperature and relative humidity (RH) both influence how pleasant a place is to be in. Monitors that display real-time measurements like JUTECH's Analog Humidity-
Specs and Features of JUTECH Humidity - Temperature Meter:
The JUTECH Humidity Temperature Meter measures interior temperature and humidity quickly and precisely, making it ideal for usage in office buildings, warehouses, manufacturing facilities, and server rooms, among other places.
In addition, you may get the dew point and wet bulb temperature from the easy-to-use measurement device. Both numbers provide information about the temperature-humidity connection and critically evaluate the interior environment. It is easy to use and has reliable technology.
The JUTECH Humidity Temperature Meter has a built-in NTC temperature sensor that provides excellent temperature measurement accuracy. This thermo hygrometer uses a capacitive humidity sensor known for its long-term durability to detect humidity.
Temperature and humidity readings are visible on the LED display of the thermo hygrometer. Additional features include dew point and wet bulb temperature calculations and min. /maximum values for these parameters. Temperature and humidity measurements may be made with the JUTECH Humidity Temperature Meter's clip-on protective hat, wrist strap, and belt.