Siglent
Function/Arbitray Generator 20MHZ Siglent SDG1020
Siglent SDG1020 Function/Arbitrary Generator 20MHZ capable of creating Sine, Square, Ramp, Pulse, Gaussian White noise & 48 types of built-in arbitrary waveform.
Function/Arbitray Generator 10MHZ Siglent SDG1010
Siglent SDG1010 Function/Arbitrary Generator 10MHZ capable of creating Sine, Square, Ramp, Pulse, Gaussian White noise & 48 types of built-in arbitrary waveform.
100MHZ Handheld Scope with Multi-Meter Siglent SHS810
Siglent SHS810, 100MHZ Handheld Scope in spite of its economic cost but capable of performing multi-meter and recorder function.
60MHZ Handheld Scope with Multi-Meter Siglent SHS806
Siglent SHS806, 60MHZ Handheld Scope in spite of its economic cost but capable of performing dual-Input, multi-meter and recorder function.
150MHZ Desktop/Bench Scope Siglent SDS1152CML
Siglent SDS1152CML 150MHZ Desktop/Bench Scope is capable of performing Electronic circuit design and bebugging.
100MHZ 4 Channels Desktop/Bench Scope Siglent SDS1104CFL
Siglent SDS1104CFL 100MHZ, 4 channels Desktop/Bench Scope is used to perform product, circuilt function test.
100MHZ Desktop/Bench Scope Siglent SDS1102CML
Siglent SDS1102CML 100MHZ / 1GS/s Desktop/Bench Scope is an useful instrument for testing signals.
25MHZ Basic Desktop/Bench Scope Siglent SDS1022DL
Siglent SDS1022DL, 25MHZ is a basic Desktop/Bench Scope usually use in school and cost effective industrial application.
Clock
Conductivity-TDS Tester
Control, Process, Display
Dissolved Oxygen (DO) Meter
Electrical
Electronic
Environmental
Gas Detector
Gas Detector Calibration Singapore
Confined places have fewer or no exits or entryways. These properties make it possible for gas levels to shift quickly, making the atmosphere hazardous with little warning. Entrants and whole watchers in confined spaces need to know if the place is safe and if conditions are going toward danger to make informed judgments regarding their safety in advance.
What is the Risk?
Dangerous gases are only one of the many dangers that might develop when working in a small area. Hazardous gases in enclosed areas pose a significant risk to workers exposed to fumes, vapours, or oxygen deprivation, leading to unconsciousness or asphyxiation.
How is the Gas Detector Protected?
The best gas detector Confined space allows you to test the environment before entering, measure continuously while inside and is simple to use and dependable to rely on.
Gas Detector Confined space monitors for dangerous fumes, gases and vapours, and oxygen deprivation to maintain occupational health and safety compliance to safeguard workers from harm. The concentration of combustible gases can be monitored with a personal multi-gas monitor, and an alarm will sound if concentrations are near the Lower Explosive Limit.
Our Gas Detector Works Best:
Numerous Gas Detector Confined space and leak detection devices are available from JUTECH. We hope to make gas leak detection more precise with our devices while making it as easy as possible.
Our technologies have been enhanced to provide trustworthy and high-quality goods throughout the years. Our gas detectors are custom-made to meet the needs of a wide range of industrial applications. It doesn't matter where our clients are, they can rely on them to quickly and accurately detect and avoid problems.
Why is Calibration Important?
Operating gas detection instruments and systems that are not kept up to date may not provide any warning of a hazardous leak or the presence of a potentially life-threatening environment. Gas detector calibration Singapore, servicing, and inspection are all essential parts of the maintenance process for any gas detection system.
Our Calibration Service:
In addition to supplying equipment, we offer consultation services for the customization, installation, and maintenance of gas monitoring systems and a variety of gas detector calibration Singapore and repair services, from essential calibration to sensor replacements and repairs.
Robust sensor technology and calibration offer faster reactions in our gas detectors. Respond in milliseconds instead of minutes or hours, and you could save a life.
Regular Checkup:
You must first calibrate your gas detector to guarantee that it accurately detects gas levels. The monitor must be calibrated by exposing it to a known calibration gas concentration or test gas for a predetermined period. Using this reading as a reference point, the gas detector will take future readings. To ensure reliable measurements, repeat this method every month. Gas detector calibration in Singapore is necessary because sensors wander over time, and toxins and inhibitors can alter gas readings.
You'll need calibration gas and tubing, a docking station, and a timer for automatic calibration. You can use a docking station to keep track of your gas detector's calibration history and create certifications for compliance when you calibrate your device.
Industrial & Mechanical
Multifunctional Tester
Multimeter
Power Converter / Charger
Process Calibrator
Telecom
Temperature & Humidity
Humidity Temperature Meter
One of the most used techniques is taking readings of the air's temperature and humidity. A reputable humidity meter is needed for accurate readings. Objects may be measured in terms of their heat or coolness by using temperature.
Temperature is one of the seven basic physical variables in the ISU. Humidity is defined as the quantity of water vapour in the air. The most common method of expressing relative humidity is as a percentage. Temperature and RH go hand in hand. In confined gas, higher temperatures diminish relative humidity. Humidity measures the amount of water vapour in the air. The relative humidity is the ratio of water vapour in the air to total water vapour
Measurement is necessary to ensure no abnormalities in the industry's temperature and humidity systems.
What is the Need for a Humidity Temperature Meter?
Measurement of temperature and humidity is necessary for temperature and humidity control systems to work. In addition, it guarantees a safe working environment and the safe storage of raw materials, components, completed goods, and equipment in excellent condition. Numerous temperature and humidity sensors are placed all over the place in almost every lab, warehouse, production hall, and workroom.
Temperature and humidity measurements are used in all labs, research institutions, and industries, including security, pharmaceutical, calibration laboratories, aviation, metals, and castings. Cement is used in various products, from seeds to medical equipment to colleges, museums to nuclear reactors. It is also used in various other products, including crystals, semiconductors, electronics, food and beverages, and optics.
Temperature and relative humidity (RH) both influence how pleasant a place is to be in. Monitors that display real-time measurements like JUTECH's Analog Humidity-
Specs and Features of JUTECH Humidity - Temperature Meter:
The JUTECH Humidity Temperature Meter measures interior temperature and humidity quickly and precisely, making it ideal for usage in office buildings, warehouses, manufacturing facilities, and server rooms, among other places.
In addition, you may get the dew point and wet bulb temperature from the easy-to-use measurement device. Both numbers provide information about the temperature-humidity connection and critically evaluate the interior environment. It is easy to use and has reliable technology.
The JUTECH Humidity Temperature Meter has a built-in NTC temperature sensor that provides excellent temperature measurement accuracy. This thermo hygrometer uses a capacitive humidity sensor known for its long-term durability to detect humidity.
Temperature and humidity readings are visible on the LED display of the thermo hygrometer. Additional features include dew point and wet bulb temperature calculations and min. /maximum values for these parameters. Temperature and humidity measurements may be made with the JUTECH Humidity Temperature Meter's clip-on protective hat, wrist strap, and belt.